Anaesthesia Machine Model 40
Description
Features
-
Built-in 8” color anesthesia ventilator
-
Traditional CO₂ absorber (autoclavable, Patent)
-
Dual high-end precise vaporizers (Volume > 280ml)
-
Dual gas sources system (O₂/N₂O)
-
Continuous FiO₂ monitoring & bain circuit interface
-
Electronic tidal volume (Innovation)
-
Battery backup for all systems over 60 mins
-
Optional: Backup Yoke system (O₂, N₂O)
-
Optional: Anesthesia gas scavenging system
-
Optional: Anesthesia gas modular patient monitor
-
ABS Structure
-
Large pressure gauges for easy reading
-
CO₂ absorber with easy change-over system
-
Optional: Yoke system for backup 1xO₂, 1xN₂O A-Type cylinder
Safety Features
-
Gas interlocking system with hypoxy guard
-
Oxygen exhaust alarm
-
Blow-off valve in top circuit
Technical Specification
Anaesthesia Main Unit
-
High-resolution 8” color TFT LCD screen
-
Dual-end pressure flow sensor for monitoring:
-
Tidal Volume
-
Respiratory frequency
-
Airway pressure
-
Pressure-time wave
-
Flow-time wave (two-way)
-
High and Low Pressure limitations
-
Apnea
-
Oxygen concentration (Auto/Manual)
-
-
Respiration loop function: Close, Semi-close, Semi-open
-
Application: Adult, Pediatric
-
Low gas alarming: Alerts if gas supply lasts under 7 seconds
-
High pressure limitation: Safety shutoff for overpressure
-
Low pressure protection: Auto stop for N₂O if O₂ pressure < 0.1 MPa
-
Power failure alarming & extendable function
-
O₂ flush: 25 ~ 75L/min
-
Gas pressure:
-
O₂: 0.3 ~ 0.5 MPa
-
N₂O: 0.3 ~ 0.5 MPa
-
-
Power supply: 220V±10%, 50Hz±1%; Backup USB Battery
-
Optional: Yoke system for backup O₂, N₂O cylinders
Flow Meter
-
O₂, N₂O – Four tubes (0.05 ~ 1 L/min, 1 ~ 10 L/min)
-
O₂/N₂O inter-lock system to keep O₂ concentration ≥ 25%
Anaesthesia Ventilator
-
Adult, Pediatric bellows 1 set each
-
Pneumatic driven electric control
-
Monitor parameters:
-
Tidal Volume
-
Respiratory frequency
-
I:E ratio
-
M.V.
-
FiO₂
-
Apnea
-
Peak airway pressure
-
Airway pressure waves
-
-
Working Modes: Manual, Auto (IPPV, SIGH, SIMV, SIPPV, Demo, optional PCV, PSV)
-
Tidal Volume: 50 ~ 1500 mL
-
Respiratory Frequency: 4 ~ 99 bpm
-
I:E Ratio: 1.0:5 ~ 1:8 (Adjustable)
-
Trigger Pressure: -2 ~ 0 kPa
-
High pressure limitation: 2 ~ 6 kPa
-
Low pressure limitation: 0 ~ 2 kPa
Respiratory Circuit
-
Compact CO₂ absorber (Autoclavable)
Vaporizer
-
High-end precise vaporizers (Halothane, Isoflurane, Sevoflurane)
-
Adjustable ranges:
-
Halothane/Isoflurane: 0.5 ~ 5% VOL
-
Sevoflurane: 0.5 ~ 8% VOL
-
-
Automatic compensation function (flow, pressure, temperature)
-
Self-lock function & inter-lock function
-
Volume: >280 mL