Anesthesia Workstation Model 30

30 people are viewing this right now
Estimated Delivery:
06 - 13 Apr, 2026
Trust Badge
Guaranteed safe & secure checkout

Description

Features
  • Built in 8” color LCD anaesthesia ventilator

  • Traditional CO₂ absorber (autoclavable, Patent)

  • Dual high end precise vaporizers (Volume > 280ml)

  • Dual gas sources system (O₂/N₂O)

  • Continuous FiO₂ monitoring & bain circuit interface

  • Optional: Electronic tidal volume setting

  • Optional: Anaesthesia gas modular patient monitor

  • Optional: Anaesthesia gas scavenging system

  • Optional: Yoke system & EtCO₂ monitoring function

  • Optional: UPS battery backup system

Technical Specification

Anaesthesia main unit

  • High resolution 8” color TFT LCD screen

  • Built with airway pressure sensor, FiO₂ sensor & flow sensor. The unit can monitor:

    • Tidal volume, Respiratory frequency, I:E rate, Airway pressure, Pressure-time wave, Flow-time wave, High pressure limitation, Low pressure limitation, MV, Apnea, FiO₂, Oxygen concentration under both two operating modes (Auto, Manual)

  • Close, semi-close, semi-open system, open (bain circuit)

  • Application: Adult, Pediatric

  • Low gas alarming: Low O₂ gas pressure, it will give alarm for more than 7 seconds.

  • High pressure limitation: Whenever airway pressure exceeds the pre-set high pressure, the ventilator offers protection automatically to ensure airway pressure does not increase further, ensuring patient safety.

  • Low pressure protection: Once O₂ pressure is less than 0.1 MPa, N₂O gas supply will stop automatically.

  • Power failure alarming, power extendable function

  • O₂ flush: 25 ~ 75L/min

  • Gas pressure:

    • O₂: 0.3 ~ 0.5 MPa

    • N₂O: 0.3 ~ 0.5 MPa

  • Power: 220V±10%, 50Hz±1%

Flow meter

  • O₂/N₂O – double tubes (0.1 ~ 10 L/min)

  • O₂/N₂O inter-lock system, to keep O₂ concentration no less than 25%

Anaesthesia Ventilator

  • Adult or Pediatric bellow 1 set

  • Pneumatic driven electric control

  • Monitor Parameters:

    • Tidal volume, Respiratory frequency, I:E rate, FiO₂,

    • Peak airway pressure, airway pressure wave (P-T, F-T), Minute volume

  • Working mode: Manual, Auto (IPPV, SIMV, SIPPV, Demo, Optional PCV, PSV)

  • Tidal volume: 50 ~ 1500 mL

  • Respiratory frequency: 4 ~ 99 bpm

  • I:E Ratio: 1.0:5 ~ 1:8 (adjustable)

  • Synchronizer trigger Pressure: -2 ~ 0 kPa

  • High pressure limitation: 2 ~ 6 kPa

  • Low pressure limitation: 0 ~ 2 kPa

Respiratory Circuit

  • Consolidated CO₂ absorber (autoclavable)

Vaporizer

  • High-end precise vaporizer (Halothane, Isoflurane, Sevoflurane)

  • Halothane/Isoflurane adjustable range: 0.5 ~ 5% VOL

  • Sevoflurane adjustable range: 0.5 ~ 8% VOL

  • Automatic compensation function – flow, pressure, temperature

  • Self-lock function & inter-lock function

  • Volume: >280 ml